Split System Installation: Best Locations for Indoor Heads

Choosing where to place the indoor head of a split system seems simple until you live with a bad decision. I’ve seen brand‑new units short‑cycling because the head faces a hallway, filters clogging twice as fast thanks to kitchen grease, and people sleeping under a draft they thought would feel “barely there.” Good placement saves energy, keeps rooms comfortable, and extends the life of the system. Poor placement costs you comfort and money, even if the equipment itself is top shelf.

This guide walks through the practical factors that drive indoor head placement, room by room. It also covers mistakes that experienced techs still see, how to plan for piping runs and condensate, and when a fresh air path or a different head style makes sense. Whether you’re hiring an ac installation service, comparing quotes for a residential ac installation, or considering an ac replacement service that reuses existing lines, you’ll be able to evaluate recommendations with confidence.

What the Indoor Head Actually Does in the Room

A split system head isn’t just a pretty box that blows cold air. It measures room temperature at or near the intake, modulates a variable‑speed fan to mix air, and removes moisture through a cold coil that drains to a condensate line. The intake pulls from the top or front, the supply throws air forward and usually slightly downward. That geometry matters, because the head will “see” the temperature near its intake more than in far corners.

Two truths shape placement. First, the unit needs to throw air across the longest dimension of the room to mix properly, otherwise it cools the zone near the head, senses setpoint, then throttles back while the far side remains warm. Second, the head should not be mounted where heat sources or sunlight bias the sensor, or where throw is blocked by large furniture or a bulkhead.

Manufacturers publish throw distances and recommended mounting heights. For common 9k to 18k BTU wall‑mounted heads, the sweet spot is a clear wall with at least 6 to 8 inches above the unit to the ceiling, 4 to 6 inches on the sides, and an unobstructed path 10 to 25 feet forward. Higher capacities or low‑static ducted heads have different needs, but the principles stay the same.

Height and Wall Choice, Explained With Real Rooms

Walk the room and ask two questions. Where will people sit, sleep, and work, and where does the sun hit? Then look at wall length and what’s behind those walls. The mounting height is usually 7 to 8 feet to keep the intake away from floor dust while using the ceiling for longer throw. Going tight to the ceiling reduces stratification but can choke return airflow if there is crown molding or a beam. Aim for a finger’s thickness of clearance times four, not “as tight as it looks good.”

On wall choice, prefer interior walls when possible. They stay closer to room temperature in winter, avoid direct sun, and make condensate routing easier if you’re draining to an interior plumbing stack. Exterior walls are common and fine, but mind solar gain and noise transmission, particularly in wood‑framed houses.

One example: a 14 by 22 foot living room with windows along the 22 foot wall. A head on one of the https://pastelink.net/jvdtjq3i 14 foot side walls can throw across the long dimension. If the south window bakes the room after lunch, do not mount above that window trim even if the line set route would be shorter. Go to the interior side wall near the hallway opening, throw air toward the window wall, and let the unit’s swing function push air along the glass.

Avoid Sensors Lying to You

Every split head has a thermistor that tells the outdoor unit how hard to work. If the intake breathes air that is warmer or cooler than the room average, it will misjudge. Here are the top offenders I see in service calls:

    Direct sun landing on the head for more than an hour a day. A TV or floor lamp below the head warming the intake plume. A supply register from another system aimed at the head. Tight alcoves that recirculate the head’s own cold supply back into the intake.

A client in a brick townhouse called to complain their new air conditioner installation wasn’t cooling the den. The head sat over a media console with a soundbar that ran hot. The thermistor saw 84 while the rest of the room was 78, so the unit hammered at high speed, over‑dehumidified, and made the space clammy. We lifted the head 10 inches and slid it laterally away from the electronics, then adjusted the vane angle to throw across the seating area. Problem solved in under two hours with no change to the equipment.

Doors, Hallways, and Open Floor Plans

In a closed bedroom, life is easy. In a rambling open plan, it is not. You want the head to mix air within its target zone without spending its energy conditioning adjacent spaces that you did not size it for. Doorways act like leaks. If the head faces a hall, it will send a chunk of its capacity straight down that corridor, then sense a slower temperature drop near the intake and run longer. Sometimes that’s desirable, especially if the hallway serves several rooms that depend on the hall to share conditioned air. More often, it undermines comfort in the main room.

If you must mount on a wall that faces a door, position the head so the primary throw runs parallel to the opening, not straight through it. Tilt the vanes to create a shallow “sheet” of air along the ceiling toward the far wall rather than a fast stream down the hall. With many modern heads, a fan speed reduction and vane swing pattern can be set per room use. If your ac installation near me tells you software controls alone will fix a bad location, press for a wall choice that does most of the work mechanically.

Bedrooms: Quiet, Draft‑Free, Reliable

Most complaints after a residential ac installation come from bedrooms, because people notice drafts at night. Mounting above the headboard seems intuitive because it hides the unit from sight lines. It also sends cold air down your scalp at 2 a.m. A better rule is to mount perpendicular to the bed, on the wall adjacent to the headboard or on the opposite wall, then angle vanes to sweep across the room rather than at the sleepers.

For a 12 by 14 bedroom, a 7 to 7.5 foot mounting height on the long wall opposite the bed works well. Keep the unit at least 3 feet from the nearest corner so the intake is not “corner loaded.” If you have a ceiling fan, mount the head so the fan helps distribute, not fight, the supply air. Low speed fan, blades moving air downward in summer, can smooth temperature and let you raise the setpoint by a degree or two without feeling sticky.

Bathrooms adjacent to bedrooms tempt installers to route lines through short wall cavities. That is fine if the cavity is dry and there is a straight path for condensate with proper slope. It is not fine if a future vanity upgrade or tile job makes that cavity inaccessible. Ask the ac installation service to map the exact path in their install notes. You will thank yourself when you remodel.

Living Rooms and Great Rooms: Throw Across the Long Dimension

Large spaces need either more capacity, more heads, or both. A single 12k head struggling to stir a 500 square foot great room will run high fan speeds and create a draft. Consider two smaller heads placed on opposing walls, each sized for its zone within the space. Place them so their throw patterns overlap slightly in the center of the room. This creates even mixing without either unit sensing setpoint too early.

Windows pull heat, kitchens generate it, and vaulted ceilings trap it. In rooms with cathedral ceilings, avoid mounting heads too high up the rake. The intake will live in warmer air than the occupied zone and the unit will chase that upstairs heat. Better to mount lower on a knee wall or a flat section, then angle supply upward slightly to break stratification while still washing the space at eye level. If the architecture forces a high mount, choose a head with long throw and strong vertical vane control, and plan for a destratification ceiling fan.

Kitchens and Dining Areas: Moisture, Grease, and Smells

I rarely recommend a head directly in a kitchen. Cooking adds moisture and aerosols that load the head’s filter and coil. If it must serve the kitchen, mount it just outside the working triangle, often on the dining side of a pass‑through or on a wall that looks into the kitchen but sits outside the cooking zone. The air will circulate without pulling a plume of steam and grease straight into the intake.

In one retrofit, a client insisted on a head above a range hood because it centralised the layout. Three months later, the coil was tacky and draining poorly. We relocated the head to the opposite wall, two studs away from the doorway, and added a short return grille in the dining soffit for better crossflow. The hood’s capture improved and the head stayed clean.

Home Offices: Sun, Screens, and Noise

Mount away from screens to avoid the localized heat plumes that bias the intake. If the room has one large window, favor the interior wall opposite it. That allows the unit to wash the window wall with cool air, taming solar gain, and keep the intake in air representative of the room average. Keep the head out of the camera frame if you take calls. Even quiet heads can create a faint hiss that a laptop mic will pick up at certain angles. Side‑wall placement at chest height looks tempting for cable routing, but wall‑mounted heads are engineered for higher placement; install as designed.

Condensate: Slope, Traps, and Where the Water Goes

If an indoor head cannot drain by gravity, expect trouble. You need at least a quarter inch of fall per foot of run on the condensate line, with smooth, supported routing and no sags that form water pockets. Long flat runs encourage biofilm and odors. Mini pumps solve elevation issues, but pumps bring noise, maintenance, and one more device that can fail. Use them as a last resort, not a default.

Route the drain to a code‑compliant termination. That might be an indirect tie‑in to a lavatory tailpiece with an air gap, or an exterior termination with a screened outlet. In humid climates, insulate the drain if it runs through warm cavities to prevent condensation on the outside of the pipe. On exterior wall penetrations, slope the last section outward and use a drip loop so water does not wick back along the line set.

I inspected a call where droplets formed at a drywall seam below a head. The installer had run the drain laterally, dead flat, for 12 feet. The line sagged between strapping points and created a hidden trap. Once we repitched the run and added rigid support at 18 inch intervals, the problem vanished.

Line Set Routing and Aesthetics

The shortest path is not always the best path. A clean vertical drop to grade with a tidy line cover reads intentional and vents any wall cavity moisture risk. A zigzag through rafters to save six feet of exterior cover often results in added friction losses on the refrigerant and extra joints that can leak. Fewer fittings, larger sweep bends, and lines sized per the manufacturer are not negotiable if you want long compressor life.

On brick or stone facades, plan penetrations through mortar joints, not the face of the brick. Paint line covers to match trim or choose low‑profile covers that align with downspouts. If you are paying for an affordable ac installation, ask whether the quote includes line hide and paint. Cheaper bids sometimes leave insulation and tape exposed to UV, which degrades quickly.

Dealing With Noise and Vibration

Modern heads are quiet, often below 30 dBA at low speed, but placement can amplify noise. On thin walls, vibration can telegraph into a bedroom or stairwell. Use the manufacturer’s mounting plate with all fasteners, add rubber isolators where specified, and avoid mounting directly on shared walls in duplexes if you can. Keep the head away from corners that act like horns. If you have a baby’s room on the other side of the wall, mount on an adjacent wall or add a backing board that spreads the load.

Outdoor noise matters too. If the line set forces you to place the head on a wall that puts the condenser right outside a frequently used patio, reconsider. Sometimes swapping walls keeps the condenser on a side yard and the indoor head in a better acoustic zone.

Unique Head Styles and When to Use Them

Wall‑mounted heads are versatile and cost‑effective, but they are not always the best choice.

    Floor consoles shine in rooms with low knee walls or sloped ceilings. They bathe the room in low‑level air that feels gentle, great for reading chairs and older occupants sensitive to drafts. Place them along exterior walls to counter downdrafts from windows. Ceiling cassettes work in rooms with clean joist bays or drop ceilings. They distribute air in four directions and disappear visually. Place them near the room center, not tucked by a beam. Slim ducted units hide in soffits or closets and serve small zones with short ducts. They require planning for return and supply paths, filter access, and condensate, but deliver the most even conditions.

When considering a split system installation for a long, narrow suite, a pair of slim ducted units may beat two wall heads, especially if you care about aesthetics or have wall space committed to art or shelving.

Heat Mode Changes the Rules

Cooling dictates throw and sun avoidance. Heating cares about where cold air pools. In heat pump mode, the head should counter downdrafts from glass and wash the occupied zone without blasting ankles. If your winters are serious, favor placement that warms the floor area and allows slow, continuous mixing. Mounting opposite large windows helps. Some heads can sense floor temperature indirectly by analyzing return air behavior; they perform best when their intake is not trapped in a warm bubble near the ceiling.

Defrost cycles in winter will temporarily stop indoor fans. Heads that sit directly over seating can create a noticeable comfort swing in these moments. Side placement reduces the perception of the cycle.

Sizing, Setpoints, and Short Cycling

Bad placement exposes bad sizing. An oversized head in a small room will satisfy quickly, then shut down before it dehumidifies. Place that same head facing a doorway and it will over‑cool the doorway zone while leaving the bed area perpetually sticky. If your installer suggests a 12k unit for a 120 square foot bedroom because “the smallest we stock is a 12,” push back. A proper air conditioner installation pairs sizing, placement, and usage patterns.

Mitsubishi, Daikin, Fujitsu, LG, and others publish minimum modulation levels. If the smallest unit still bottoms out above the room’s sensible load for most of the season, choose a multi‑zone outdoor with multiple small heads, or a single‑zone with a lower minimum, or a slim ducted solution that serves two rooms with one air handler. Good ac replacement service providers will show you these options rather than force‑fit a single SKU.

Humidity and Fresh Air Considerations

In humid climates, the head’s coil must see warm, moist air long enough to condense. Heads mounted above doors that swing open to the outside may gulp hot, wet air in short bursts, then shut down as the thermostat senses a quick drop. This leads to extended fan‑only periods that re‑evaporate moisture off the coil. If you hear “the room feels cool but clammy,” suspect poor air mixing and fan settings tied to a suboptimal location.

Split systems do not magically bring in fresh air. If your home is tight, consider whether the area served by a head needs a dedicated fresh air source, such as an ERV tied into a slim ducted unit or a small wall supply with a motorized damper controlled by a timer. When fresh air is added, avoid placing the head so it immediately recirculates that outdoor air back into its intake without mixing.

Historic Homes and Tricky Construction

Plaster walls, balloon framing, and stone foundations change your options. Stud finders lie on lath, and surprise chases hide behind chair rail. In these homes, I test drill in inconspicuous spots, snake a camera, and adjust the plan. If an exterior wall mount means drilling through 14 inches of fieldstone, I will often choose an interior wall that lets me drop into a basement, run concealed line sets, then pop outside near the condenser with a clean penetration.

Mounting plates must be leveled carefully on wavy plaster. A quarter‑bubble out of level will put the condensate pan on edge, and the corner will drip on humid days. Add blocking if the wall is soft, and use longer, appropriate anchors. I have seen heads hanging on two sheetrock screws that missed studs entirely. Do not be that story.

Maintenance Access and Filter Hygiene

You need to reach the head to clean filters every one to three months, depending on pets and dust. Mount above a tall bookcase and those filter tabs become theoretical. An owner who cannot reach them will not clean them, and the coil will mat up. Leave at least a foot of clear space beneath the bottom of the head for a step stool and hands. If there is a drapery rod, mount above it or on the adjacent wall. Face fabric absorbs dust; the intake will pull it in like a vacuum.

Service clearances matter. Can a tech remove the front cover without contorting? Is there room to catch condensate when cleaning the coil? If a mini pump is present, can it be accessed without unmounting the head? These are small things until they are big.

When a Different Room Makes More Sense

Sometimes the best place for a head in a given room is still a compromise. If you find yourself accepting three compromises, step back. Move the head to a nearby space that shares air, and size and place it for that combined zone. Example: a living room and a small parlor connected by a large cased opening. Instead of one head crammed above the parlor entry fighting two return paths, mount the head centered on the larger living room wall, throwing across the opening, and allow mixing to carry into the parlor. Alternatively, use two smaller heads if doors regularly close between the spaces.

Coordinating With Other Systems

If you have existing forced air or hydronic heating, avoid direct conflicts. A supply register aimed at the head will skew its sensor. A baseboard heater below a head will bake it in winter. Shift the head laterally or choose a different wall. If you plan to use the split primarily for cooling while a furnace handles heating, factor that into placement. In cooling, the head can live closer to a south window to tame solar gain, since winter heat bias won’t matter as much. If the split will heat in shoulder seasons, still avoid above‑baseboard placement.

Home automation can help, but it cannot fix physics. A remote sensor mounted on an interior wall can nudge control logic in some brands. Just remember that air still has to move. Do not place a remote sensor in a corner far from the head and expect uniform comfort if the throw cannot reach that corner.

Cost and Aesthetics Trade‑offs

An affordable ac installation often balances labor and materials against ideal placement. Moving a head six feet to the right might mean running lines behind cabinets or opening a chase, which adds a half day to the job. Sometimes the budget says no. The technician’s job is to propose the best option within constraints, not shrug and mount in the easiest spot. As the homeowner, decide where you care most: visibility, noise, comfort gradients, or first cost.

If you are comparing quotes from an air conditioner installation or ac installation near me search, look beyond price. Ask each bidder to sketch the head location on a floor plan and explain their reasoning. The installer who talks about throw, solar gain, condensate slope, and furniture layout is the one who will get you a better result than the one who says “we always put it above the window.”

A Simple Pre‑Install Walkthrough You Can Use

Here’s a short checklist you can run with your installer before any split system installation:

    Stand in each room and point to where people sit, sleep, cook, or work. Confirm the head won’t blow directly on those spots. Identify the longest room dimension and choose a wall that lets the head throw along it without blasting through a doorway or hall. Check sun patterns. If direct sun hits the candidate wall for more than an hour, explore another wall or shading. Plan the condensate path with gravity first. If a pump is unavoidable, choose a quiet model, confirm access, and route the discharge to a proper termination. Confirm line set routing, insulation, and line hide. Fewer joints, clean penetrations, and UV‑resistant covers keep the system reliable and tidy.

Final Judgment Calls From the Field

When I walk into a house for a new ac installation or a thoughtful ac replacement service, I assume every room will ask for a trade‑off. I prioritize consistent mixing over minimal visibility. I protect the sensor from bias rather than fight it with settings. I avoid pumps unless a gravity path is truly impossible. I keep service access in mind, because a head that cannot be maintained will not stay efficient.

Most importantly, I listen to how the space is used. A hobby room where someone stands at a workbench calls for a different vane angle and maybe a different wall than a room used for yoga on the floor. A nursery wants the gentlest breeze and the quietest defrost transitions. A sunroom with three walls of glass may be better served by two smaller heads placed to wash the glass than by one oversized unit that short‑cycles.

If you keep those principles close and ask your installer to defend their placement with specifics, you will end up with a split system that feels invisible in the best sense. It will just work, summer and winter, without drawing attention, and your filters will tell the story of proper placement by how slowly they load. That is the real mark of a good air conditioner installation.